| Network | Code | Name | Latitude | Longitude | Elevation [m] | Status | Start | End | Created |
|---|---|---|---|---|---|---|---|---|---|
| RO | MANR | Mangalia | 43.816800 | 28.587600 | 72.00 | open | 2008/10/10 | None | 2008/10/10 |
| Channel | Sensor type | Sensor description | Sensor model | Sensor manufacturer | Datalogger | Sensitivity value | Sensitivity frequency | Input units name | Output units name |
|---|---|---|---|---|---|---|---|---|---|
| EHE | Mark Products | Mark Products L4C/Quanterra 330 Linear Phase Compo | Products | Mark | n/a | 48559100 | 4 | M/S | n/a |
| EHN | Mark Products | Mark Products L4C/Quanterra 330 Linear Phase Compo | Products | Mark | n/a | 48559100 | 4 | M/S | n/a |
| EHZ | Mark Products | Mark Products L4C/Quanterra 330 Linear Phase Compo | Products | Mark | n/a | 48559100 | 4 | M/S | n/a |
| HNE | Episensor 200 | Episensor 200 Hz 10 Volt FS 2g/Quanterra 330 Linea | 200 | Episensor | n/a | 427475 | 0.02 | M/S**2 | n/a |
| HNN | Episensor 200 | Episensor 200 Hz 10 Volt FS 2g/Quanterra 330 Linea | 200 | Episensor | n/a | 427475 | 0.02 | M/S**2 | n/a |
| HNZ | Episensor 200 | Episensor 200 Hz 10 Volt FS 2g/Quanterra 330 Linea | 200 | Episensor | n/a | 427475 | 0.02 | M/S**2 | n/a |
| LCE | n/a | n/a | n/a | n/a | n/a | 1000000 | 0 | M/S | n/a |
| LCQ | n/a | n/a | n/a | n/a | n/a | 1 | 0 | M/S | n/a |
| SHE | Mark Products | Mark Products L4C/Quanterra 330 Linear Phase Compo | Products | Mark | n/a | 47201100 | 2 | M/S | n/a |
| SHN | Mark Products | Mark Products L4C/Quanterra 330 Linear Phase Compo | Products | Mark | n/a | 47201100 | 2 | M/S | n/a |
| SHZ | Mark Products | Mark Products L4C/Quanterra 330 Linear Phase Compo | Products | Mark | n/a | 47201100 | 2 | M/S | n/a |
| VCO | n/a | n/a | n/a | n/a | n/a | 6.66667 | 0 | M/S | n/a |
| VEA | n/a | n/a | n/a | n/a | n/a | 1000 | 0 | M/S | n/a |
| VEC | n/a | n/a | n/a | n/a | n/a | 1000 | 0 | M/S | n/a |
| VEP | n/a | n/a | n/a | n/a | n/a | 6.66667 | 0 | M/S | n/a |
| VKI | n/a | n/a | n/a | n/a | n/a | 1 | 0 | M/S | n/a |
| VMU | n/a | n/a | n/a | n/a | n/a | 10 | 0 | M/S | n/a |
| VMV | n/a | n/a | n/a | n/a | n/a | 10 | 0 | M/S | n/a |
| VMW | n/a | n/a | n/a | n/a | n/a | 10 | 0 | M/S | n/a |
| VPB | n/a | n/a | n/a | n/a | n/a | 10 | 0 | M/S | n/a |
| BHE | Guralp CMG40T.1to100/Quanterra | Guralp CMG40T.1to100/Quanterra 330 Linear Phase Co | CMG40T.1to100/Quanterra | Guralp | n/a | 329847000 | 0.3 | M/S | n/a |
| BHN | Guralp CMG40T.1to100/Quanterra | Guralp CMG40T.1to100/Quanterra 330 Linear Phase Co | CMG40T.1to100/Quanterra | Guralp | n/a | 329847000 | 0.3 | M/S | n/a |
| BHZ | Guralp CMG40T.1to100/Quanterra | Guralp CMG40T.1to100/Quanterra 330 Linear Phase Co | CMG40T.1to100/Quanterra | Guralp | n/a | 329847000 | 0.3 | M/S | n/a |
| HHE | Guralp CMG40T.1to100/Quanterra | Guralp CMG40T.1to100/Quanterra 330 Linear Phase Co | CMG40T.1to100/Quanterra | Guralp | n/a | 329857000 | 0.7 | M/S | n/a |
| HHN | Guralp CMG40T.1to100/Quanterra | Guralp CMG40T.1to100/Quanterra 330 Linear Phase Co | CMG40T.1to100/Quanterra | Guralp | n/a | 329857000 | 0.7 | M/S | n/a |
| HHZ | Guralp CMG40T.1to100/Quanterra | Guralp CMG40T.1to100/Quanterra 330 Linear Phase Co | CMG40T.1to100/Quanterra | Guralp | n/a | 329857000 | 0.7 | M/S | n/a |
| BDF | Chapparral 2.5 | Chapparral 2.5 microphone/Basalt Linear Phase Comp | 2.5 | Chapparral | n/a | 44587.9 | 0.3 | PA | n/a |
| BHE | BB Seismometer/Basalt | BB Seismometer/Basalt Linear Phase Composite | Seismometer/Basalt | BB | n/a | 926787000 | 0.2 | M/S | n/a |
| BHN | BB Seismometer/Basalt | BB Seismometer/Basalt Linear Phase Composite | Seismometer/Basalt | BB | n/a | 926787000 | 0.2 | M/S | n/a |
| BHZ | BB Seismometer/Basalt | BB Seismometer/Basalt Linear Phase Composite | Seismometer/Basalt | BB | n/a | 926787000 | 0.2 | M/S | n/a |
| HHE | BB Seismometer/Basalt | BB Seismometer/Basalt Linear Phase Composite | Seismometer/Basalt | BB | n/a | 926790000 | 0.4 | M/S | n/a |
| HHN | BB Seismometer/Basalt | BB Seismometer/Basalt Linear Phase Composite | Seismometer/Basalt | BB | n/a | 926790000 | 0.4 | M/S | n/a |
| HHZ | BB Seismometer/Basalt | BB Seismometer/Basalt Linear Phase Composite | Seismometer/Basalt | BB | n/a | 926790000 | 0.4 | M/S | n/a |
| HNE | Episensor 200 | Episensor 200 Hz 10 Volt FS 2g/Basalt Linear Phase | 200 | Episensor | n/a | 427475 | 0.02 | M/S**2 | n/a |
| HNN | Episensor 200 | Episensor 200 Hz 10 Volt FS 2g/Basalt Linear Phase | 200 | Episensor | n/a | 427475 | 0.02 | M/S**2 | n/a |
| HNZ | Episensor 200 | Episensor 200 Hz 10 Volt FS 2g/Basalt Linear Phase | 200 | Episensor | n/a | 427475 | 0.02 | M/S**2 | n/a |
| LCE | n/a | n/a | n/a | n/a | n/a | 1000000 | 0 | M/S | n/a |
| LCQ | n/a | n/a | n/a | n/a | n/a | 1 | 0 | M/S | n/a |
| VCO | n/a | n/a | n/a | n/a | n/a | 6.66667 | 0 | M/S | n/a |
| VEA | n/a | n/a | n/a | n/a | n/a | 1000 | 0 | M/S | n/a |
| VEC | n/a | n/a | n/a | n/a | n/a | 1000 | 0 | M/S | n/a |
| VEP | n/a | n/a | n/a | n/a | n/a | 6.66667 | 0 | M/S | n/a |
| VKI | n/a | n/a | n/a | n/a | n/a | 1 | 0 | M/S | n/a |
| VMU | n/a | n/a | n/a | n/a | n/a | 10 | 0 | M/S | n/a |
| VMV | n/a | n/a | n/a | n/a | n/a | 10 | 0 | M/S | n/a |
| VMW | n/a | n/a | n/a | n/a | n/a | 10 | 0 | M/S | n/a |
| VPB | n/a | n/a | n/a | n/a | n/a | 10 | 0 | M/S | n/a |
| Description |
|---|
| Firstname | Lastname | Department | Agency | City | Street | Country | Phone | |
|---|---|---|---|---|---|---|---|---|
| n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Description |
|---|
| Geological Unit | Morphology Class | Ground Type EC8 | Groundwater Depth [m] | Vs 30 [m/s] | f0 [Hz] | Amp(f0) | Basin Flag | Bedrock Depth [m] |
|---|---|---|---|---|---|---|---|---|
| 0 | 0 | 0 | 0 | False | 0 |
| Description |
|---|
| Housing Class | In Building? | Number of storeys | Distance to building |
|---|---|---|---|
| True | 0 | 0 |
| Depth [m] |
|---|
| 0 |
| Description | Top depth [m] | Bottom depth [m] |
|---|