FDSNWS-Station Data:

Network Code Name Latitude Longitude Elevation [m] Status Start End Created
IV VITU Vitulano 41.183260 14.630154 848.00 open 2013/12/30 None 2013/12/30

FDSNWS-Station Instrumentation Data:

Channel Sensor type Sensor description Sensor model Sensor manufacturer Datalogger Sensitivity value Sensitivity frequency Input units name Output units name
EHE n/a LENNARTZ LE3D-5S n/a n/a INGV GAIA2-FS-10-VPP 503316000.0 1.0 m/s count
EHN n/a LENNARTZ LE3D-5S n/a n/a INGV GAIA2-FS-10-VPP 503316000.0 1.0 m/s count
EHZ n/a LENNARTZ LE3D-5S n/a n/a INGV GAIA2-FS-10-VPP 503316000.0 1.0 m/s count
HHE n/a NANOMETRICS TRILLIUM-40S n/a n/a INGV GAIA2-FS-16-VPP 1179650000.0 0.2 m/s count
HHN n/a NANOMETRICS TRILLIUM-40S n/a n/a INGV GAIA2-FS-16-VPP 1179650000.0 0.2 m/s count
HHZ n/a NANOMETRICS TRILLIUM-40S n/a n/a INGV GAIA2-FS-16-VPP 1179650000.0 0.2 m/s count
HNE n/a KINEMETRICS EPISENSOR-FBA-ES-T-CL-2G-FS-40-VPP n/a n/a INGV GAIA2-FS-40-VPP 320770.0 0.2 m/s**2 count
HNN n/a KINEMETRICS EPISENSOR-FBA-ES-T-CL-2G-FS-40-VPP n/a n/a INGV GAIA2-FS-40-VPP 320770.0 0.2 m/s**2 count
HNZ n/a KINEMETRICS EPISENSOR-FBA-ES-T-CL-2G-FS-40-VPP n/a n/a INGV GAIA2-FS-40-VPP 320770.0 0.2 m/s**2 count
HHZ n/a Trillium Compact, 120 s, 1500 V/m/s Trillium Compact 120 (Vault, Posthole, OBS) Nanometrics Centaur, 40 vpp (gain 1), 100 sps, DC removal filter on (1 mHz), Linear phase 599999407.481 1.0 m/s count
HHN n/a Trillium Compact, 120 s, 1500 V/m/s Trillium Compact 120 (Vault, Posthole, OBS) Nanometrics Centaur, 40 vpp (gain 1), 100 sps, DC removal filter on (1 mHz), Linear phase 599999407.481 1.0 m/s count
HHE n/a Trillium Compact, 120 s, 1500 V/m/s Trillium Compact 120 (Vault, Posthole, OBS) Nanometrics Centaur, 40 vpp (gain 1), 100 sps, DC removal filter on (1 mHz), Linear phase 599999407.481 1.0 m/s count
HNZ n/a Episensor, DC to >200 Hz,20V differential full scale voltage, 2g clip level Episensor (ES-T, ES-U, ES-U2, DS-DH, SBEPI), +/- 20V Differential Kinemetrics Centaur, 40 vpp (gain 1), 200 sps, DC removal filter on (1 mHz), Linear phase 407879.796941 1.0 m/s**2 count
HNN n/a Episensor, DC to >200 Hz,20V differential full scale voltage, 2g clip level Episensor (ES-T, ES-U, ES-U2, DS-DH, SBEPI), +/- 20V Differential Kinemetrics Centaur, 40 vpp (gain 1), 200 sps, DC removal filter on (1 mHz), Linear phase 407879.796941 1.0 m/s**2 count
HNE n/a Episensor, DC to >200 Hz,20V differential full scale voltage, 2g clip level Episensor (ES-T, ES-U, ES-U2, DS-DH, SBEPI), +/- 20V Differential Kinemetrics Centaur, 40 vpp (gain 1), 200 sps, DC removal filter on (1 mHz), Linear phase 407879.796941 1.0 m/s**2 count

Basic Data:

Description

Owner Data:

Firstname Lastname Department Agency City Street Country Phone Email
n/a n/a n/a n/a n/a n/a n/a n/a n/a

Morphology Data:

Description
Geological Unit Morphology Class Ground Type EC8 Groundwater Depth [m] Vs 30 [m/s] f0 [Hz] Amp(f0) Basin Flag Bedrock Depth [m]
0 0 0 0 False 0

Housing Data:

Description
Housing Class In Building? Number of storeys Distance to building
True 0 0

Borehole Data:

Depth [m]
0

Borehole Layers:

Description Top depth [m] Bottom depth [m]