FDSNWS-Station Data:

Network Code Name Latitude Longitude Elevation [m] Status Start End Created
IV RUFI RUFI 43.838000 11.509500 243.00 open 2012/12/6 None 2012/12/6

FDSNWS-Station Instrumentation Data:

Channel Sensor type Sensor description Sensor model Sensor manufacturer Datalogger Sensitivity value Sensitivity frequency Input units name Output units name
EHZ n/a Lennartz_LE-3Dlite-MkII_LP1_SG400_STgroundVel n/a n/a INGV_GAIA2_FV10Vpp_FR100 +5.07891E+08 20.75 m/s count
EHN n/a Lennartz_LE-3Dlite-MkII_LP1_SG400_STgroundVel n/a n/a INGV_GAIA2_FV10Vpp_FR100 +5.07891E+08 20.75 m/s count
EHE n/a Lennartz_LE-3Dlite-MkII_LP1_SG400_STgroundVel n/a n/a INGV_GAIA2_FV10Vpp_FR100 +5.07891E+08 20.75 m/s count
EHZ n/a Lennartz; LE-3Dlite-MkII; Long-Period_Corner 1 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 10Vpp; Final_Sample_Rate 100 Hz +6.72198E+08 20.75 m/s count
EHN n/a Lennartz; LE-3Dlite-MkII; Long-Period_Corner 1 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 10Vpp; Final_Sample_Rate 100 Hz +6.72198E+08 20.75 m/s count
EHE n/a Lennartz; LE-3Dlite-MkII; Long-Period_Corner 1 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 10Vpp; Final_Sample_Rate 100 Hz +6.72198E+08 20.75 m/s count
HHZ n/a Lunitek; TELLUS; Long-Period_Corner 10 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 40Vpp; Final_Sample_Rate 100 Hz +1.67806E+08 21.2 m/s count
HHN n/a Lunitek; TELLUS; Long-Period_Corner 10 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 40Vpp; Final_Sample_Rate 100 Hz +1.67806E+08 21.2 m/s count
HHE n/a Lunitek; TELLUS; Long-Period_Corner 10 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 40Vpp; Final_Sample_Rate 100 Hz +1.67806E+08 21.2 m/s count
HHZ n/a Lunitek; TELLUS; Long-Period_Corner 10 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 20Vpp; Final_Sample_Rate 100 Hz +3.35612E+08 21.2 m/s count
HHN n/a Lunitek; TELLUS; Long-Period_Corner 10 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 20Vpp; Final_Sample_Rate 100 Hz +3.35612E+08 21.2 m/s count
HHE n/a Lunitek; TELLUS; Long-Period_Corner 10 s; Sensitivity 400 V/m/s; Sensor_Type groundVel n/a n/a INGV; GAIA-IV; Full-Scale_Voltage 20Vpp; Final_Sample_Rate 100 Hz +3.35612E+08 21.2 m/s count

Basic Data:

Description

Owner Data:

Firstname Lastname Department Agency City Street Country Phone Email
n/a n/a n/a n/a n/a n/a n/a n/a n/a

Morphology Data:

Description
Geological Unit Morphology Class Ground Type EC8 Groundwater Depth [m] Vs 30 [m/s] f0 [Hz] Amp(f0) Basin Flag Bedrock Depth [m]
0 0 0 0 False 0

Housing Data:

Description
Housing Class In Building? Number of storeys Distance to building
True 0 0

Borehole Data:

Depth [m]
0

Borehole Layers:

Description Top depth [m] Bottom depth [m]